Spatiotemporally Defining Biomolecule Preconcentration by Merging Ion Concentration Polarization

Rhokyun Kwak, Ji Yoon Kang, Tae Song Kim

Research output: Contribution to journalArticle

17 Citations (Scopus)

Abstract

The ion concentration polarization (ICP) phenomenon at micronanofluidic interfaces has been extensively utilized to preconcentrate low-abundance biological samples. Although preconcentration by ICP is robust, its multiphysics phenomenon does not permit a clear prediction of the preconcentration conditions and sites. Here, we present a new method for spatiotemporally defining preconcentration, which can generate target-condensed plugs in a very specific region (<100 μm) regardless of the operating conditions (time, applied voltage, ionic strength, and pH). In contrast to previous devices that use only ion depletion, this device uses merged ICP zones with opposite polarity, i.e., ion depletion and ion enrichment. In this regard, ICP is initiated between two line-patterned cation exchange membranes. When voltage is applied across two membranes, an ion depletion (enrichment) zone occurs on the anodic (cathodic) side of the membranes. Two ICP zones are then merged and confined between the membranes. Consequently, the preconcentration action is also confined between the membranes. We demonstrate that fluorescent dyes are always preconcentrated at the designated location at all lengths of operating time and at broad voltage (0.5-100 V), ionic strength (1-100 mM KCl), and pH (3.7-10.3) ranges. This device successfully condenses proteins up to 10000-fold in a specific region of the channel (100 × 50 × 10 μm3) in 10 min. This work not only characterizes the unique scientific phenomenon of ICP overlapping but also opens the possibility of integrating ICP preconcentrators into commercial analysis equipment, which requires a known, stationary preconcentration site.

Original languageEnglish
Pages (from-to)988-996
Number of pages9
JournalAnalytical Chemistry
Volume88
Issue number1
DOIs
StatePublished - 2016 Jan 5

Fingerprint

Biomolecules
Merging
Ions
Polarization
Membranes
Ionic strength
Electric potential
Fluorescent Dyes
Cations

Cite this

@article{61c7ad51cb4c4d24bf8183f0c4b2dcf2,
title = "Spatiotemporally Defining Biomolecule Preconcentration by Merging Ion Concentration Polarization",
abstract = "The ion concentration polarization (ICP) phenomenon at micronanofluidic interfaces has been extensively utilized to preconcentrate low-abundance biological samples. Although preconcentration by ICP is robust, its multiphysics phenomenon does not permit a clear prediction of the preconcentration conditions and sites. Here, we present a new method for spatiotemporally defining preconcentration, which can generate target-condensed plugs in a very specific region (<100 μm) regardless of the operating conditions (time, applied voltage, ionic strength, and pH). In contrast to previous devices that use only ion depletion, this device uses merged ICP zones with opposite polarity, i.e., ion depletion and ion enrichment. In this regard, ICP is initiated between two line-patterned cation exchange membranes. When voltage is applied across two membranes, an ion depletion (enrichment) zone occurs on the anodic (cathodic) side of the membranes. Two ICP zones are then merged and confined between the membranes. Consequently, the preconcentration action is also confined between the membranes. We demonstrate that fluorescent dyes are always preconcentrated at the designated location at all lengths of operating time and at broad voltage (0.5-100 V), ionic strength (1-100 mM KCl), and pH (3.7-10.3) ranges. This device successfully condenses proteins up to 10000-fold in a specific region of the channel (100 × 50 × 10 μm3) in 10 min. This work not only characterizes the unique scientific phenomenon of ICP overlapping but also opens the possibility of integrating ICP preconcentrators into commercial analysis equipment, which requires a known, stationary preconcentration site.",
author = "Rhokyun Kwak and Kang, {Ji Yoon} and Kim, {Tae Song}",
year = "2016",
month = "1",
day = "5",
doi = "10.1021/acs.analchem.5b03855",
language = "English",
volume = "88",
pages = "988--996",
journal = "Analytical chemistry",
issn = "0003-2700",
number = "1",

}

Spatiotemporally Defining Biomolecule Preconcentration by Merging Ion Concentration Polarization. / Kwak, Rhokyun; Kang, Ji Yoon; Kim, Tae Song.

In: Analytical Chemistry, Vol. 88, No. 1, 05.01.2016, p. 988-996.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Spatiotemporally Defining Biomolecule Preconcentration by Merging Ion Concentration Polarization

AU - Kwak, Rhokyun

AU - Kang, Ji Yoon

AU - Kim, Tae Song

PY - 2016/1/5

Y1 - 2016/1/5

N2 - The ion concentration polarization (ICP) phenomenon at micronanofluidic interfaces has been extensively utilized to preconcentrate low-abundance biological samples. Although preconcentration by ICP is robust, its multiphysics phenomenon does not permit a clear prediction of the preconcentration conditions and sites. Here, we present a new method for spatiotemporally defining preconcentration, which can generate target-condensed plugs in a very specific region (<100 μm) regardless of the operating conditions (time, applied voltage, ionic strength, and pH). In contrast to previous devices that use only ion depletion, this device uses merged ICP zones with opposite polarity, i.e., ion depletion and ion enrichment. In this regard, ICP is initiated between two line-patterned cation exchange membranes. When voltage is applied across two membranes, an ion depletion (enrichment) zone occurs on the anodic (cathodic) side of the membranes. Two ICP zones are then merged and confined between the membranes. Consequently, the preconcentration action is also confined between the membranes. We demonstrate that fluorescent dyes are always preconcentrated at the designated location at all lengths of operating time and at broad voltage (0.5-100 V), ionic strength (1-100 mM KCl), and pH (3.7-10.3) ranges. This device successfully condenses proteins up to 10000-fold in a specific region of the channel (100 × 50 × 10 μm3) in 10 min. This work not only characterizes the unique scientific phenomenon of ICP overlapping but also opens the possibility of integrating ICP preconcentrators into commercial analysis equipment, which requires a known, stationary preconcentration site.

AB - The ion concentration polarization (ICP) phenomenon at micronanofluidic interfaces has been extensively utilized to preconcentrate low-abundance biological samples. Although preconcentration by ICP is robust, its multiphysics phenomenon does not permit a clear prediction of the preconcentration conditions and sites. Here, we present a new method for spatiotemporally defining preconcentration, which can generate target-condensed plugs in a very specific region (<100 μm) regardless of the operating conditions (time, applied voltage, ionic strength, and pH). In contrast to previous devices that use only ion depletion, this device uses merged ICP zones with opposite polarity, i.e., ion depletion and ion enrichment. In this regard, ICP is initiated between two line-patterned cation exchange membranes. When voltage is applied across two membranes, an ion depletion (enrichment) zone occurs on the anodic (cathodic) side of the membranes. Two ICP zones are then merged and confined between the membranes. Consequently, the preconcentration action is also confined between the membranes. We demonstrate that fluorescent dyes are always preconcentrated at the designated location at all lengths of operating time and at broad voltage (0.5-100 V), ionic strength (1-100 mM KCl), and pH (3.7-10.3) ranges. This device successfully condenses proteins up to 10000-fold in a specific region of the channel (100 × 50 × 10 μm3) in 10 min. This work not only characterizes the unique scientific phenomenon of ICP overlapping but also opens the possibility of integrating ICP preconcentrators into commercial analysis equipment, which requires a known, stationary preconcentration site.

UR - http://www.scopus.com/inward/record.url?scp=84953431830&partnerID=8YFLogxK

U2 - 10.1021/acs.analchem.5b03855

DO - 10.1021/acs.analchem.5b03855

M3 - Article

C2 - 26642086

AN - SCOPUS:84953431830

VL - 88

SP - 988

EP - 996

JO - Analytical chemistry

JF - Analytical chemistry

SN - 0003-2700

IS - 1

ER -