Soil damping formulation in nonlinear time domain site response analysis

Duhee Park, Youssef M.A. Hashash

Research output: Contribution to journalArticle

9 Citations (Scopus)

Abstract

Nonlinear time domain site response analysis is used to capture the soil hysteretic response and nonlinearity due to medium and large ground motions. Soil damping is captured primarily through the hysteretic energy dissipating response. Viscous damping, using the Rayleigh damping formulation, is often added to represent damping at very small strains where many soil models are primarily linear. The Rayleigh damping formulation results in frequency dependent damping, in contrast to experiments that show that the damping of soil is mostly frequency independent. Artificially high damping is introduced outside a limited frequency range that filters high frequency ground motion. The extended Rayleigh damping formulation is introduced to reduce the over- damping at high frequencies. The formulation reduces the filtering of high frequency motion content when examining the motion Fourier spectrum. With appropriate choice of frequency range, both formulations provide a similar response when represented by the 5% damped elastic response spectrum. The proposed formulations used in non-linear site response analysis show that the equivalent linear frequency domain solution commonly used to approximate non-linear site response underestimates surface ground motion within a period range relevant to engineering applications. A new guideline is provided for the use of the proposed formulations in non-linear site response analysis.

Original languageEnglish
Pages (from-to)249-274
Number of pages26
JournalJournal of Earthquake Engineering
Volume8
Issue number2
DOIs
StatePublished - 2004 Jan 1

Fingerprint

response analysis
damping
Damping
Soils
soil
ground motion
nonlinearity
filter
engineering

Keywords

  • Deep deposits
  • Equivalent linear
  • Frequency- domain
  • Nonlinear
  • Site response
  • Time-domain
  • Viscous damping
  • Wave propagation

Cite this

@article{aa63660c91e44446b29d03dadff8abb7,
title = "Soil damping formulation in nonlinear time domain site response analysis",
abstract = "Nonlinear time domain site response analysis is used to capture the soil hysteretic response and nonlinearity due to medium and large ground motions. Soil damping is captured primarily through the hysteretic energy dissipating response. Viscous damping, using the Rayleigh damping formulation, is often added to represent damping at very small strains where many soil models are primarily linear. The Rayleigh damping formulation results in frequency dependent damping, in contrast to experiments that show that the damping of soil is mostly frequency independent. Artificially high damping is introduced outside a limited frequency range that filters high frequency ground motion. The extended Rayleigh damping formulation is introduced to reduce the over- damping at high frequencies. The formulation reduces the filtering of high frequency motion content when examining the motion Fourier spectrum. With appropriate choice of frequency range, both formulations provide a similar response when represented by the 5{\%} damped elastic response spectrum. The proposed formulations used in non-linear site response analysis show that the equivalent linear frequency domain solution commonly used to approximate non-linear site response underestimates surface ground motion within a period range relevant to engineering applications. A new guideline is provided for the use of the proposed formulations in non-linear site response analysis.",
keywords = "Deep deposits, Equivalent linear, Frequency- domain, Nonlinear, Site response, Time-domain, Viscous damping, Wave propagation",
author = "Duhee Park and Hashash, {Youssef M.A.}",
year = "2004",
month = "1",
day = "1",
doi = "10.1080/13632460409350489",
language = "English",
volume = "8",
pages = "249--274",
journal = "Journal of Earthquake Engineering",
issn = "1363-2469",
number = "2",

}

Soil damping formulation in nonlinear time domain site response analysis. / Park, Duhee; Hashash, Youssef M.A.

In: Journal of Earthquake Engineering, Vol. 8, No. 2, 01.01.2004, p. 249-274.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Soil damping formulation in nonlinear time domain site response analysis

AU - Park, Duhee

AU - Hashash, Youssef M.A.

PY - 2004/1/1

Y1 - 2004/1/1

N2 - Nonlinear time domain site response analysis is used to capture the soil hysteretic response and nonlinearity due to medium and large ground motions. Soil damping is captured primarily through the hysteretic energy dissipating response. Viscous damping, using the Rayleigh damping formulation, is often added to represent damping at very small strains where many soil models are primarily linear. The Rayleigh damping formulation results in frequency dependent damping, in contrast to experiments that show that the damping of soil is mostly frequency independent. Artificially high damping is introduced outside a limited frequency range that filters high frequency ground motion. The extended Rayleigh damping formulation is introduced to reduce the over- damping at high frequencies. The formulation reduces the filtering of high frequency motion content when examining the motion Fourier spectrum. With appropriate choice of frequency range, both formulations provide a similar response when represented by the 5% damped elastic response spectrum. The proposed formulations used in non-linear site response analysis show that the equivalent linear frequency domain solution commonly used to approximate non-linear site response underestimates surface ground motion within a period range relevant to engineering applications. A new guideline is provided for the use of the proposed formulations in non-linear site response analysis.

AB - Nonlinear time domain site response analysis is used to capture the soil hysteretic response and nonlinearity due to medium and large ground motions. Soil damping is captured primarily through the hysteretic energy dissipating response. Viscous damping, using the Rayleigh damping formulation, is often added to represent damping at very small strains where many soil models are primarily linear. The Rayleigh damping formulation results in frequency dependent damping, in contrast to experiments that show that the damping of soil is mostly frequency independent. Artificially high damping is introduced outside a limited frequency range that filters high frequency ground motion. The extended Rayleigh damping formulation is introduced to reduce the over- damping at high frequencies. The formulation reduces the filtering of high frequency motion content when examining the motion Fourier spectrum. With appropriate choice of frequency range, both formulations provide a similar response when represented by the 5% damped elastic response spectrum. The proposed formulations used in non-linear site response analysis show that the equivalent linear frequency domain solution commonly used to approximate non-linear site response underestimates surface ground motion within a period range relevant to engineering applications. A new guideline is provided for the use of the proposed formulations in non-linear site response analysis.

KW - Deep deposits

KW - Equivalent linear

KW - Frequency- domain

KW - Nonlinear

KW - Site response

KW - Time-domain

KW - Viscous damping

KW - Wave propagation

UR - http://www.scopus.com/inward/record.url?scp=85023921636&partnerID=8YFLogxK

U2 - 10.1080/13632460409350489

DO - 10.1080/13632460409350489

M3 - Article

AN - SCOPUS:85023921636

VL - 8

SP - 249

EP - 274

JO - Journal of Earthquake Engineering

JF - Journal of Earthquake Engineering

SN - 1363-2469

IS - 2

ER -