Present status of hanbit magnetic mirror device

S. M. Hwang, G. S. Lee, J. G. Yang, K. K. Choh, J. H. Choi, J. W. Choi, K. S. Chung, C. J. Dhoh, J. Hong, B. C. Kim, D. E. Kim, W. C. Kim, H. K. Lee, S. G. Lee, H. K. Na, Y. K. Oh, H. L. Yang, S. J. Yoo, N. S. Yoon, K. I. YouDuk In Choi

Research output: Contribution to journalArticle

22 Scopus citations

Abstract

The Hanbit magnetic mirror device, which is operated as a joint plasma research facility, has been constructed at Korea Basic Science Institute for basic study and technology development of high temperature plasma confinement, plasma heating and diagnostics, and plasma applications, such as high-temperature material testing for tokamak divertors. A 500-kW RF transmitter and a 100-kW RF transmitter for ICRF heating are major heating sources in operation, and a few gyrotron-based ECRH systems are in preparation. The target plasma parameters at the central cell are 1-keV ion temperature, 200-eV electron temperature, and 5 × 1012 cm-3 electron density with 500-ms plasma duration. The present status of the Hanbit device, which includes the system overview and recent experimental result, is described in this paper, and future plans will be discussed.

Original languageEnglish
Pages (from-to)99-106
Number of pages8
JournalFusion Technology
Volume35
Issue number1 SPEC. ISS.
Publication statusPublished - 1999 Dec 1

    Fingerprint

Cite this

Hwang, S. M., Lee, G. S., Yang, J. G., Choh, K. K., Choi, J. H., Choi, J. W., ... Choi, D. I. (1999). Present status of hanbit magnetic mirror device. Fusion Technology, 35(1 SPEC. ISS.), 99-106.