Design of the multi-reflection time-of-flight mass spectrometer for the RAON facility

J. W. Yoon, Y. H. Park, S. J. Park, G. D. Kim, Y. K. Kim

Research output: Contribution to journalConference article

5 Citations (Scopus)

Abstract

Electrodes design for the multi-reflection time-of-flight mass spectrometer (MR-TOF-MS) has been performed for the high precision mass measurement system in RAON accelerator facility, which will be constructed in Korea. Calculated mass resolution is 105 for the condition of an energy spread of ± 30 eV and an emittance of 0.75 π mm mrad. MR-TOF-MS will be used for the isobar separation and the mass measurement for very short-lived isotopes.

Original languageEnglish
Article number11042
JournalEPJ Web of Conferences
Volume66
DOIs
StatePublished - 2014 Apr 14
Event2013 International Nuclear Physics Conference, INPC 2013 - Firenze, Italy
Duration: 2013 Jun 22013 Jun 7

Fingerprint

mass spectrometers
Korea
isobars
emittance
accelerators
isotopes
electrodes
energy

Cite this

@article{7358d1ff99644870ac29b7a9bd70a256,
title = "Design of the multi-reflection time-of-flight mass spectrometer for the RAON facility",
abstract = "Electrodes design for the multi-reflection time-of-flight mass spectrometer (MR-TOF-MS) has been performed for the high precision mass measurement system in RAON accelerator facility, which will be constructed in Korea. Calculated mass resolution is 105 for the condition of an energy spread of ± 30 eV and an emittance of 0.75 π mm mrad. MR-TOF-MS will be used for the isobar separation and the mass measurement for very short-lived isotopes.",
author = "Yoon, {J. W.} and Park, {Y. H.} and Park, {S. J.} and Kim, {G. D.} and Kim, {Y. K.}",
year = "2014",
month = "4",
day = "14",
doi = "10.1051/epjconf/20146611042",
language = "English",
volume = "66",
journal = "EPJ Web of Conferences",
issn = "2101-6275",

}

Design of the multi-reflection time-of-flight mass spectrometer for the RAON facility. / Yoon, J. W.; Park, Y. H.; Park, S. J.; Kim, G. D.; Kim, Y. K.

In: EPJ Web of Conferences, Vol. 66, 11042, 14.04.2014.

Research output: Contribution to journalConference article

TY - JOUR

T1 - Design of the multi-reflection time-of-flight mass spectrometer for the RAON facility

AU - Yoon, J. W.

AU - Park, Y. H.

AU - Park, S. J.

AU - Kim, G. D.

AU - Kim, Y. K.

PY - 2014/4/14

Y1 - 2014/4/14

N2 - Electrodes design for the multi-reflection time-of-flight mass spectrometer (MR-TOF-MS) has been performed for the high precision mass measurement system in RAON accelerator facility, which will be constructed in Korea. Calculated mass resolution is 105 for the condition of an energy spread of ± 30 eV and an emittance of 0.75 π mm mrad. MR-TOF-MS will be used for the isobar separation and the mass measurement for very short-lived isotopes.

AB - Electrodes design for the multi-reflection time-of-flight mass spectrometer (MR-TOF-MS) has been performed for the high precision mass measurement system in RAON accelerator facility, which will be constructed in Korea. Calculated mass resolution is 105 for the condition of an energy spread of ± 30 eV and an emittance of 0.75 π mm mrad. MR-TOF-MS will be used for the isobar separation and the mass measurement for very short-lived isotopes.

UR - http://www.scopus.com/inward/record.url?scp=84898717919&partnerID=8YFLogxK

U2 - 10.1051/epjconf/20146611042

DO - 10.1051/epjconf/20146611042

M3 - Conference article

AN - SCOPUS:84898717919

VL - 66

JO - EPJ Web of Conferences

JF - EPJ Web of Conferences

SN - 2101-6275

M1 - 11042

ER -